40Gbps 10km LC QSFP + Transceiver
katrangan2
Parameter Spesifikasi QSFP + Transceiver
jeneng | 40G mode tunggal | ||
Nomer model | ZHLQ-1640G-10 | Merk | Zhilian Hengtong |
Jinis paket | QSFP+ | Tingkat transmisi | 40G |
Dawane ombak | 1310nm | Jarak transmisi | 10 km |
Pelabuhan | LC | Jinis serat | 9/125µm SMF |
jinis laser | CWDM | Tipe panrima | PIN-TIA |
Daya optik sing dikirim | -7~+2.3dBm | Nampa sensitivitas | -11.5dbm |
daya | Nampa kakehan | 2.3dBm | |
Dissipation daya |
| Rasio kepunahan | ≥3.5DB |
CDR (Clock Data Recovery) |
| Fungsi FEC |
|
Suhu komersial | 0~70 ℃ | kasepakatan | SFF-8436/SFF- 8636/IEEE802.3ba |
Diagram Blok Modul

Fitur Transceiver QSFP +
Aplikasi QSFP + Transceiver
Standar
Lingkungan Operasi sing Disaranake
Parameter | Simbol | Min. | khas | Maks. | Unit |
Tegangan Pasokan Daya | VCC | 3.13 | 3.3 | 3.46 | Ing |
Power Supply Saiki | ICC |
|
| 1000 | m.a. |
Dissipasi Daya | PD |
|
| 3.5 | ING |
Suhu Kasus Operasi | TC | 0 |
| +70 | C |
Agregat Data Rate | - |
| 41.25 |
| Gbps |
Bit Rate saben Lane | BR |
| 10.3125 |
| Gbps |
Karakteristik Listrik
Parameter | Simbol | Min. | khas | Maks. | Unit | Cathetan |
Bagian Pemancar |
| |||||
Impedansi Diferensial Input | ugi | 90 | 100 | 110 | Oh |
|
Swing Input Data Diferensial | Anggur PP | 180 |
| 1000 | mV | 1 |
Bagian Penerima |
| |||||
Diferensial Data Output Swing | Wulan PP | 300 |
| 850 | mV |
Parameter Optik
Parameter | Simbol | Min. | khas | Maks. | Unit | Cathetan |
Bagian Pemancar | ||||||
Panjang Gelombang Lane Center (rentang) | λ0 | 1264.5 | 1271 | 1277.5 | nm |
|
l 1 | 1284.5 | 1291 | 1297.5 | nm |
| |
λ2 | 1304.5 | 1311 | 1317.5 | nm |
| |
λ3 | 1324.5 | 1331 | 1337.5 | nm |
| |
Jembar Spektral (-20dB) | Dl |
|
| 1 | nm |
|
Rasio Pandhet Mode Sisih | SMSR | 30 |
|
| dB |
|
Rata-rata Daya Optik saben Lane | Pout | -7.0 |
| +2.3 | dBm | 1 |
Daya OMA saben Lane | DIRI | -4 |
| 3.5 | dBm | 1 |
Laser Off Power saben Lane | Poof | - | - | -30 | dBm |
|
Rasio kepunahan | IS | 3.5 | - | - | dB | 2 |
Noise Intensitas Relatif | UGI | - | - | -128 | dB/Hz |
|
Optical Bali Mundhut Toleransi |
| - | - | 20 | dB |
|
Definisi topeng mripat pemancar {X1, X2, X3, Y1, Y2, Y3} | Selaras karo IEEE802.3ba {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} | 2 | ||||
Bagian Penerima |
| |||||
Panjang Gelombang Lane Center (rentang) | λ0 | 1264.5 |
| 1277.5 | nm |
|
l 1 | 1284.5 |
| 1297.5 | nm |
| |
λ2 | 1304.5 |
| 1317.5 | nm |
| |
λ3 | 1324.5 |
| 1337.5 | nm |
| |
Rata-rata daya panrima saben Lane | RXPX | -13.7 |
| 2.3 | dBm | 3 |
Sensitivitas OMA saben Lane | RXsens |
|
| -11.5 | dBm | 3 |
The Asserts | RELEASE | -30 | - | - | dBm |
|
Go Dessert | LOSD | - | - | -16 | dBm |
|
Ing Hysteresis | LOSH | 0.5 | - | 5 | dB |
|
Overload saben Lane | Pin-maks | - | - | 2.3 | dBm | 3 |
Reflectance panrima |
| - | - | -12 | dB |
|
Ambang karusakan saben Lane |
| - | - | 3.5 | dBm |
Fungsi Diagnostik Digital
Ukuran Mekanik